General Description:
Hai Bang 3 Phase 12kV Vacuum Contactor – Type CKG8 is applicable on AC 50-60Hz power systems, rated voltage 7.2kV and 12kV, rated operational current 800, 1000A, 1250A, 1600A, 2000A. This type of 3 Phase 12kV Vacuum Contactor is used to directly or remotely connect and disconnect the main circuit, and to control electrical equipment such as non-inductive AC motors and transformers.
We have another type of 12kV(7.2kV) 3 Phase Vacuum Contactor, whose rated current are 160A, 250A, 400A, 630A. Please refer to the categories for more information.
Types:
CKG8-7.2J/D-800-3.2
CKG8-7.2J/D-1000-10
CKG8-7.2J/D-1250-12.5
CKG8-7.2J/D-1600-12.5
CKG8-7.2J/D-2000-12.5
CKG8-12J/D-800-3.2
CKG8-12J/D-1000-10
CKG8-12J/D-1250-12.5
CKG8-12J/D-1600-12.5
CKG8-12J/D-2000-12.5
Technical Data:
Name | Unit | Value | |||||
Main circuit | Rated working voltage (Ue) | kV | 7.2kV | 12kV | |||
Rated working current (Ie) | A | 800, 1000A, 1250A, 1600A, 2000A | |||||
Rated frequency (fr) | Hz | 50~60 | |||||
Rated connecting capacity | A | 4Ie (AC-2) | |||||
Rated breaking capacity | A | 6Ie (AC-2) | |||||
Rated short time withstand current | A | 8Ie | |||||
Rated peak withstand current | A | 15Ie | |||||
Ultimate breaking capacity | A | 8Ie,3times | |||||
Rated short circuit duration | s | 2 | |||||
Power frequency withstand voltage | Wiring terminal to earth | kV | 32 | 42 | |||
Vacuum breaks | kV | 32 | 42 | ||||
Lightening impulse withstand voltage | kV | 60 | 75 | ||||
Control circuit | Rated voltage (Us) | V | AC 110/220/380 | ||||
DC 110/220 | |||||||
Rated power (Ps) electric holding | VA | ≤1000/100 (absorbing/holding) | |||||
Rated power (Ps) mechanical holding | VA | ≤900/600 (Closing/opening) | |||||
Auxiliary circuit | Form | (3a+2b)~(6a+5b) | |||||
Rated value | AC 380V/5A, | ||||||
DC 380V/1A | |||||||
Control circuit, auxiliary circuit to earth power frequency withstand voltage | kV | 2 | |||||
Rated operating frequency | Long-term | time/h | 120 | ||||
Short-term | time/h | 360 | |||||
Mechanical endurance | 10000 times | 10 | |||||
Electrical endurance | 10000 times | 25(AC-2) | |||||
Mechanical characteristics | Closing time | ms | ≤200 | ||||
3-phase asynchronous time | ms | ≤3 | |||||
Original opening time | ms | ≤60 | |||||
Closing tripping | ms | ≤10 | |||||
Remark: rated control voltage can be made according to customer’s requirements. |