Wuxi Haibang Mechanical & Electrical Manufacturing Co.,Ltd

Wuxi Haibang Mechanical & Electrical Manufacturing Co.,Ltd

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Single Phase Vacuum Contactor /

Plateau Type 1 Phase Vacuum Contactor 160A 250A 400A 630A Rated Current

Contact Now
Wuxi Haibang Mechanical & Electrical Manufacturing Co.,Ltd
Visit Website
City:wuxi
Province/State:jiangsu
Country/Region:china
Contact Person:MrMinjie
Contact Now

Plateau Type 1 Phase Vacuum Contactor 160A 250A 400A 630A Rated Current

Ask Latest Price
Video Channel
Place of Origin :china
Brand Name :haibang
Price :Negotiable
Payment Terms :Payment Terms: L/C, T/T, D/A, D/P
Type :Vacuum
Rated Frequency :50/60Hz
Phase :Single
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Hai Bang Plateau type Single phase vacuum contactor are suitable for power systems with AC 50~60Hz, main circuit rated voltage 40.5kV, and rated current 160A, 250A, 400A, 630A. JCZ1 Single phase vacuum contactor is mainly used as a grounding switch when a single-phase ground fault occurs. JCZ1 Single Phase AC Vacuum Contactor is used in arc suppression cabinets and electrical occasions that require single-phase control. The altitude of the environment where the Single phase vacuum contactor Plateau type is used does not exceed 5000 meters above sea level, thus it is a plateau type vacuum contactor.

Types:

JCZ1-40.5TG/D-160

JCZ1-40.5TG/D-250

JCZ1-40.5TG/D-400

JCZ1-40.5TG/D-630

Application Condition:

1. Ambient Air Temperature: -25℃~+40℃,24-hour average must NOT exceed +35℃;
2. Altitude: 5000m or Lower; Our patent shows the JCZ1 plateau type single phase vacuum contactor can operate safely and stably within an altitude of 5000m above sea level.
3. Relative Humidity: Daily average less than 95%, Monthly average less than 90%, Must NOT exceed 50% when Ambient Air Temperature reaches +40℃;
4. Operation Environment: Ambient air shall not be contaminated by corrosive, flammable or explosive gas and water vapor, Contamination Level: Level III;
5. Installation of single phase plateau type vacuum Contactor:
When operating, the tilt angle between the surface of installed plateau type single phase vacuum contactor and the horizontal plane shall NOT exceed 5°.

Note: In case the above conditions cannot meet the user's requirements, the user can negotiate with the manufacturer for special treatment of the product.

Technical Data:

Name

Unit

Value

Main circuit

Rated working voltage (Ue)

kV

40.5

Rated working current (Ie)

A

160, 250, 400, 630
Rated frequency (fr)

Hz

50~60
Rated connecting capacity

A

10Ie (AC-2)
Rated breaking capacity

A

8Ie (AC-2)
Ultimate breaking capacity

kA, time

6.3, 3
Rated short time withstand current

A

10Ie
Rated peak withstand current

A

25Ie
Rated short circuit duration

s

4
Power frequency withstand voltage

Wiring terminal to earth

kV

95

Vacuum breaks

kV

95
Lightening impulse withstand voltage

kV

185

Control circuit

Rated voltage (Us)

V

AC 110/220/380

DC 110/220
Rated power (Ps)electric holding

VA

≤1000/100 (absorbing/holding)

Auxiliary circuit

Form

3a+3b

Rated value AC 380V/5A
DC 380V/1A

Control circuit, auxiliary circuit to earth power frequency withstand voltage

kV

2

Rated operating frequency

Long-term

time/h

120

Short-term

time/h

360

Mechanical endurance

10000 times

3

Electrical endurance

10000 times

25(AC-3), 10(AC-4)

Mechanical characteristics

Closing time

ms

≤200

Original opening time

ms

≤100
Closing tripping

ms

≤10

Remark: Rated control voltage can be made according to customer’s requirements.