12kV 630A Vacuum Contactor - High Voltage Vacuum Contactor, rated voltage 12kV, rated current 160A, 250A, 400A, 630A
General Description:
Hai Bang 12kV 630A Vacuum Contactor is applicable on AC 50-60Hz power systems, rated voltage up to 12 kV, rated current 160A, 250A, 400A, 630A. This type of 12kV high voltage vacuum contator is widely used in power grid reactive power compensation, chemical industry, metallurgy, water supply and drainage treatment, underground coal mine equipment and other occasions. Haibang 12kV 630A Vacuum Contactor is used to directly or remotely connect and disconnect the main circuit and frequently control capacitive loads, AC motors, transformers and other electrical equipment. The altitude of the environment where the 12kV high voltage Vacuum Contactor is used does not exceed 1000 meters above sea level.
We have another type of 12kV Vacuum Contactor, whose rated current is 800A, 1000A, 1250A, 1600A, 2000A. Please refer to the categories for more information.
Types:
JCZ5-12J/D-160-1.6
JCZ5-12J/D-250-2.5
JCZ5-12J/D-400-4.0
JCZ5-12J/D-630-6.3
Technical Data:
Name | Unit | Value | ||||
Main circuit | Rated working voltage (Ue) | kV | 12 | |||
Rated working current (Ie) | A | 160A, 250A, 400A, 630A | ||||
Rated frequency (fr) | Hz | 50~60 | ||||
Rated connecting capacity | A | 10Ie (AC-4) | ||||
Rated breaking capacity | A | 8Ie (AC-4) | ||||
Rated short time withstand current | A | 10Ie | ||||
Rated peak withstand current | A | 25Ie | ||||
Rated short circuit duration | s | 4 | ||||
Ultimate breaking capacity | 6.3 kA , 3 times | |||||
Power frequency withstand voltage | Wiring terminal to earth | kV | 42 | |||
Vacuum breaks | kV | 42 | ||||
Lightening impulse withstand voltage | kV | 75 | ||||
Rated single capacitor breaking current (C2) | A | 160-400 | ||||
Control circuit | Rated voltage (Us) | V | AC or DC. 110/220 | |||
Rated power (Ps)electric holding | VA | ≤1000/100 (absorbing/holding) | ||||
Auxiliary circuit | Form | (3a+2b)~(6a+5b) | ||||
Rated value | AC 380V/5A, | |||||
DC 380V/1A | ||||||
Control circuit, auxiliary circuit to earth power frequency withstand voltage | kV | 2 | ||||
Rated operating frequency | Long-term | time/h | 300 | |||
Short-term | time/h | 600 | ||||
Mechanical endurance | 10000 times | 100 | ||||
Electrical endurance | 10000 times | 25(AC-3), 10(AC-4) | ||||
Mechanical characteristics | Closing time | ms | ≤200 | |||
3-phase asynchronous time | ms | ≤3 | ||||
Original opening time | ms | ≤160 | ||||
Closing tripping | ms | ≤10 | ||||
Remark: 1. rated control voltage can be made according to customer’s requirements. 2. For the mechanical holding type, the locking device needs to be replaced every 100,000 times. |